Portable Three-Phase Multi-function Electrical Measurement Instrument Calibrator
-
-
Large Image :
Portable Three-Phase Multi-function Electrical Measurement Instrument Calibrator
|
Product Details:
Place of Origin: |
china |
Brand Name: |
GFUVE |
Certification: |
ISO 9001 : 2008; CE |
Model Number: |
GF302 |
Payment & Shipping Terms:
Minimum Order Quantity: |
1SET |
Price: |
USD20000-35000 |
Packaging Details: |
Standard export box |
Delivery Time: |
within few working days(depends on your quantity) |
Payment Terms: |
T/T, Western Union, Paypal |
Supply Ability: |
200pcs/month |
|
Detailed Product Description
Sample Price: |
Depending On The Customs Tariff |
Category: |
Power Meters |
Class: |
0.05% |
Type: |
Electrical Measurement Instrument Calibrator |
GF302 PORTABLE MULTIFUNCTION INSTRUMENT CALIBRATOR
GF302 portable multifunction instrument calibrator is suitable for power plant and power grid companies for the following function: measuring and testing department and instrumentation classes, national levels measuring and testing institutions, railway, petroleum, chemical industry and other large industrial and mining enterprises, scientific research units, etc. The core technology function with digital signal processor (DSP) and 16 high-speed digital converters composed of high precision work frequency communication terminal. The signal source is DSP and 16 high-speed digital-to-analog converters, it can control the sine wave and distortion wave signal source.
FUNCTIONS AND FEATURES
-
All kinds of electric measurement transducer can be checked, includingAC/DC voltage transducer, AC/DC current transducer, frequency transducer, phase transducer, single/ three-phaseAC active power transducer, three-phase reactive power transducers
-
Check all kinds of electric measurement indicating meter, includingAC/DC voltmeter, AC/DC ammeter, frequency meter, phase meter, single three-phase ac active power meter, three-phase ac reactive power meter, synchronous meter, etc
-
Test single-phase, three-phase electronic, mechanical watt-hour meter or energy meter/ kWh meter error
-
Calibrate AC sample device, RTU, measurement device error
-
The built-in electric measurement transducer, electric measurement instrument and meter instructions of verification procedures, can fully automatic or semi-automatic for verification, and save 1000 group check data
-
It can be used as voltage source, current source and power source with high precision, and it isa high stability standard resource
-
6.4-inch big screen color display and English interface
-
For the software calibration, you don’t need to open the case, it’s stable and reliable
-
Voltage output terminal with short circuit, current output terminal open protection and power amplifier overheating protection function
-
With automatic failure detection function, shows fault part, the convenience users check line
-
With USB port, it can connect computer for data management or controlled by PC
PARAMETERS
Electrical parameters |
Accuracy class |
0.05%, 0.1% |
Power supply |
Single phase AC 220V±10% or 110V±10%, 50/60Hz |
Communication port |
USB, RS232 |
AC Voltage output |
Range(U1,U2,U3) |
50V, 100V, 200V, 400V, 600V |
Adjusting range |
(0-120)% RG |
Adjust fineness |
0.005% RG |
Accuracy |
0.05% RG |
Stability |
0.01% / 1 min |
Load capacity |
25VA |
Output distortion degree |
≤0.3% or (linear load) |
AC Current output |
Range(I1,I2,I3) |
0.5A, 1A, 2.5A, 5A, 10A, 20A |
Adjusting range |
(0-120)% RG |
Adjust fineness |
0.005% RG |
Accuracy |
0.05% RG |
Stability |
0.01%/1 min |
Load capacity |
25VA |
Output distortion degree |
≤0.3% or (linear load) |
AC Power output |
Accuracy |
0.05% RG |
Stability |
0.01%/1min |
Frequency |
Frequency range |
45.000 - 65.000 Hz |
Resolution |
0.001 Hz |
Accuracy |
0.002 Hz |
Power factor output |
Adjusting range |
-1 ~ 0 ~ 1 |
Adjust fineness |
0.0001 |
Accuracy |
0.0005 |
Phase angle |
Scope |
0°-359.99° |
Resolution |
0.01° |
Accuracy |
0.05° |
Voltage/Current harmonic output |
Times |
2-31st |
Content |
0-40% |
Phase |
0-359.999 degree |
Configuration error |
(10% RD + 0.1%), RD refers to the configuration value of harmonic contents |
DC Voltage output |
Range |
75mV, 75V, 150V, 300V, 500V, 1000V |
Adjusting range |
(0-120)% RG |
Adjust fineness |
0.005% RG |
Accuracy |
0.05% RG |
Stability |
0.01%/1min |
Load capacity |
25VA |
DC Current output |
Range |
0.5A, 1A, 2.5A, 5A, 10A, 20A |
Adjusting range |
(0-120)% RG |
Adjust fineness |
0.005% RG |
Accuracy |
0.05% RG |
Stability |
0.01%/1min |
Load capacity |
25VA |
DC measurements |
DC voltage measurement range |
0 to ±24V |
DC current measurement range |
0 to ±24mA |
Measurement accuracy |
0.01% RG |
Watt-hour meter measuring the integrated error |
Active energy |
0.05% |
Reactive energy |
0.1% |
Mechanical parameters |
Dimensions (W×H×D) (mm) |
460x430x185 |
Weight (kg) |
20 |
Environmental conditions |
Working temperature |
0°C to 40°C |
Storage conditions |
-30°C to 60°C |
Relative humidity |
≤85% |