Home ProductsElectrical Calibrator

GF6018A CLAMP TYPE MULTIMETER CALIBRATOR

Certification
Good quality Current Transformer for sales
I'm Online Chat Now

GF6018A CLAMP TYPE MULTIMETER CALIBRATOR

China GF6018A CLAMP TYPE MULTIMETER CALIBRATOR supplier
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR supplier GF6018A CLAMP TYPE MULTIMETER CALIBRATOR supplier

Large Image :  GF6018A CLAMP TYPE MULTIMETER CALIBRATOR

Product Details:

Place of Origin: Beijing, China
Brand Name: GFUVE
Certification: ISO9001
Model Number: GF6018A

Payment & Shipping Terms:

Packaging Details: Expore carton
Delivery Time: whitin 30 days
Payment Terms: T/T
Supply Ability: 200pcs/month
Minimum Order Quantity: 1 pcs
Contact Now
Detailed Product Description
High Light:

electrical calibrator

,

clamp meter calibrator

,

CT clamp calibrator

INTRODUCTION:

The equipment is compliance with national verification regulation: JJG124-2005

“Ammeter, voltmeter, power meter and resistance meter verification rules” and

related nationalstandards. 0.05 single-phase AC/DC standard source, can verify

magnitude 0.2and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter.

The source signals by using DSP and 16-bit high-speed analog-to-digital

converters of controllable sine wave, the distorted wave signal source.The equipment

comes with RS-232 interface, can be connected with PC to a semi-automatic

verification system. It has precise interface and multi-functions including verification,

storage and query.The equipment adopts color LCD screen, chart character display is clear,

with high precision, stable and reliable, convenient operation and flexible

FEATURES:

1. It can be semi-automatic or manual inspection of analog multi meter,

clamp type current meter, all kinds of electric meter, (voltmeter, ammeter,

frequency meters, resistance meter) basic error.

2. The equipment can be generated with 2-31 harmonic wave, harmonic number, order,

amplitude and harmonic phase of fundamental wave can be programmed.

3. Power amplifier working frequency range is 40Hz-1KHZ, has a good linear.

Current amplifier is constant current source; voltage amplifier is constant

voltage source. Because of light weight, this device is more suitable for field use.

4. With RS-232 interface, this device is controlled by PCthrough the PC software

(optional), can be automatic or manual inspection, and the results are processing

and management.

5. Has a non-volatile memory, it can store 500 pieces of the raw data

of tested meter, for access and upload.

PARAMETERS

Electrical parameters  

Power supply

Single phase AC 220V±10% or 110V±10%, 50/60HzAC

AC Voltage output  

range

200mV, 400mV, 2000mV, 4000mV,
20V, 100V, 200V, 500V, 1000V

Range 20V-1000V

Accuracy

±(0.03%RD+0.02%FS)

Stability

≤0.01% FS /60s

Range 200mV-4000mV

Accuracy

±(0.3%RD+0.2%FS)

Stability

≤0.04% FS /60s

Load capacity

20VA

Waveform distortion

≤0.3%

Adjustable Range

0-120% FS (1000V not included)

Fineness

5×10-5

AC Current Output  

Range

2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A

Range 0.2A-20A

Accuracy

±(0.03%RD+0.02%FS)

Stability

≤0.01% FS /60s

Range 2mA-40mA

Accuracy

±(0.3%RD+0.2%FS)

Stability

≤0.04% FS /60s

Load capacity

20VA

Waveform distortion

≤0.3%

Adjustable Range

0-120% FS

Fineness

5×10-5

Frequency Output  

Range

45-65Hz

Fineness

0.001Hz

Accuracy

0.01Hz

Harmonic Wave  

Times

2-31

Extent

0-20%

Each harmonic phase fineness

0.01·N (N is harmonic order)

DC voltage output  

Range

200mV, 400mV, 2000mV, 4000mV,
20V, 40V, 100V, 200V, 400V, 1000V

Load capacity

20W

Adjustable range

0-110% FS (1000V not included)

Adjustable fineness

5×10-5

Stability

≤0.01% FS /60s (peak-peak value)

Accuracy

±(0.03%RD+0.02%FS)

Ripple wave

≤1% FS

DC current output  

Range

20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A

Load capacity

20W

Adjustable Range

0-110% FS (1000V not included)

Adjustable Fineness

5×10-5

Stability

≤0.01% FS /60s (peak-peak value)

Accuracy

±(0.06%RD+0.04%FS)

Ripple wave

≤1% FS

Resistance box  

Range

0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ,
0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ

Fineness

0.02%

Range 0-2kΩ, 0-20kΩ, 0-200kΩ  

Range 0-2kΩ

Adjustable Range

0-100%FS

Accuracy

±(0.12%RD+0.08%FS)

Range 0-200Ω,0-2MΩ

Adjustable Range

0-100% FS

Accuracy

±(0.3%RD+0.2%FS)

Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ  

Range 2kΩ-4kΩ

Adjustable Range

5%-100%FS

Accuracy

±(0.12%RD+0.08%FS)

Range 200-400Ω,
2MΩ-4MΩ

Adjustable Range

5%-100% FS

Accuracy

±(0.3%RD+0.2%FS)

Clamp meter range  

200A

Accuracy

±0.2%

600A

Accuracy

±0.5%

1000A

Accuracy

±1%

Dot frequency square wave output 

Range

1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz

Square wave amplitude

4.5V

Setting accuracy

5×10-5

Mechanical parameters  

Dimension (L×W×H) (mm)

440x360x160

Weight (kg)

12

Environmental conditions 

Operating temperature

20°C±10°C

Relative humidity

≤85%RH






Contact Details
Beijing GFUVE Electronics Co.,Ltd.

Contact Person: Mr. Andy

Tel: 86-10-85782698

Fax: 86-010-85781298

Send your inquiry directly to us (0 / 3000)