Home ProductsCT Analyzer

HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER

Certification
Good quality Current Transformer for sales
I'm Online Chat Now

HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER

China HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER supplier
HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER supplier HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER supplier HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER supplier HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER supplier HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER supplier

Large Image :  HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER

Product Details:

Place of Origin: BEIJING CHINA
Brand Name: GFUVE
Certification: ISO9001, CE, UL
Model Number: GF106T

Payment & Shipping Terms:

Minimum Order Quantity: 1SET
Price: 10000USD
Packaging Details: STANDARD EXPORT WOODEN BOX
Delivery Time: 7DAYS
Payment Terms: L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram
Contact Now
Detailed Product Description
CLASS: 0.05 CT RATIO: 0-10000
PT RATIO: 0-10000 Phase Error: 4min
Ratio: 0.5% Type: Ct Analyzer
Weight: 23KG Ct Test: Automatic

GF106T HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER

HIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZERHIGH PRECISION CLASS 0.05 MEASUREMENT PORTABLE CURRENT TRANSFORMER CT ANALYZER

GF106T ct analyzer is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Withstand test of power frequency alternating current
5. Current Injecting 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Withstand test of power frequency alternating current 7. Actual secondary load test 
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test 
10. Resistance test 

PARAMETERS

Electrical parameters
Accuracy 0.2%, 0.5%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output 0-2500Vrms,
Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A
Electrical parameters - continued
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio error measurement Range 1-500KV
Accuracy ≤0.5%
Standards 
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm) 400 x 250 x 250
Weight (kg) ≤22
Environmental conditions 
Relative humidity 90RH%
Operating temperature -10°C to +40°C
Altitude ≤1000m

 

http://www.gfuve.com/transformer-test/portable-ct-pt-analyzer.html 

Contact Details
Beijing GFUVE Electronics Co.,Ltd.

Contact Person: Mr. Andy

Tel: 86-10-85782698

Fax: 86-010-85781298

Send your inquiry directly to us (0 / 3000)