Home ProductsCT Analyzer

CLASS 0.05 Full Automatic Current Transformer Accuracy Testing System

Certification
Good quality Current Transformer for sales
I'm Online Chat Now

CLASS 0.05 Full Automatic Current Transformer Accuracy Testing System

China CLASS 0.05 Full Automatic Current Transformer Accuracy Testing System supplier
CLASS 0.05 Full Automatic Current Transformer Accuracy Testing System supplier CLASS 0.05 Full Automatic Current Transformer Accuracy Testing System supplier CLASS 0.05 Full Automatic Current Transformer Accuracy Testing System supplier

Large Image :  CLASS 0.05 Full Automatic Current Transformer Accuracy Testing System

Product Details:

Place of Origin: BEIJING, CHINA
Brand Name: GFUVE
Certification: ISO9001, CE, UL
Model Number: HES-16

Payment & Shipping Terms:

Minimum Order Quantity: 1SET
Price: 30000USD
Packaging Details: STANDARD EXPORT WOODEN BOX
Delivery Time: 30DAYS
Payment Terms: D/A, L/C, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100SETS/MONTH
Contact Now
Detailed Product Description
CLASS: 0.05 WEIGHT: 300KG
PRIMARY CURRENT: 0-2500A Rated Secondary Current: 5A,1A

Full Automatic Current Transformer Accuracy Testing System

 

CLASS 0.05 Full Automatic Current Transformer Accuracy Testing System

HES-16 Full Automatic Current Transformer Accuracy Testing System

 

Remark:

  1. The above picture only for reference, the final product structure can be designed according to user`s requirements.
  2. The Bench can be installed FY49 CT Burden (5A), FY47 CT Burden (1A), HES-1C Transformer Tester, HLS-20G1 Standard CT and Current Source (inside), Computer etc.
  1. Name of the products: HES-16 Full Automatic Current Transformer Accuracy Testing System
  2. Test range and accuracy class of the testing system:
No Products Description Model Test Range Accuracy Class
1 Standard Current Transformer HLS-20G1 5A-2000A / 5A&1A ±0.01%
2 Current Burden (1A) FY47

COSΦ=0.8: 0.05VA-30VA

COSΦ=1.0: 0.05VA-10VA

±3%
3 Current Burden (5A) FY49

COSΦ=0.8: 1.25VA-30VA

COSΦ=1.0: 1.25VA-10VA

±3%
4 Transformer Tester HES-1C (1%-120%).In ±1%

 

  1. Control model of each products:
No Products Description Model Control Model
1 CT Testing Bench HES-16 Automatic control by PC & Electric controll
2 Current Burden (1A) FY47 Automatic control by PC and Manual
3 Current Burden (5A) FY49 Automatic control by PC and Manual
4 Transformer Tester HES-1C Automatic upload error datas to PC
5 Standard Current Transformer HLS-20G1 Automatic connection by PC
6 Quantity of the object CT   1-16pcs, Automatic test by PC

 

4. The list of CT test system:

No Item/Description Product Model Qty
1 Full Automatic CT Test Bench HES-16 1PC
2 Digital Transformer Tester HES-1C 1PC
3 Standard CT (with Current Source) HLS-20G1 1PC
4 Current Burden (1A) FY47 1PC
5 Current Burden (5A) FY49 1PC
6 High-Current Testing Cables   1SET
7 CT Secondary Testing Cables   1SET
8 CT Test and control Software   1PC
9 Computer and Printer   1PC
10 Laser scanner   1PC

 

 

Annex: Technical Datas of the each products

  1. HES-16 Full Automatic CT Testing Bench
  1. Input Voltage: AC 220V 50Hz Single-phase
  2. Output Voltage: AC 0-250V
  3. Rated Capacity: 10kVA
  4. Output Voltage: Coarse adjustment & Fine adjustment
  5. Adjustment Model: Automatic adjustment by PC & Electric adjustment
  6. Regulatory Elements: double-servo motor and double voltage regulator
  7. Protection functions: provided over-current and over-voltage protection
  8. The Bench can be installed: FY49 CT burden, FY47 CT burden, HES-1C Transformer Tester, Computer etc.
  9. The Bench Structure: According to user`s requirements
  10. Quantity of the tested object CT: 1-16pcs

 

2)HES-1C Digital Transformer Tester

a. Rated Current and Voltage: 5A, 1A, 100V,110V,120V

The ratio coefficient: 1/√3,1/3,1,1.5,2

b. Measuring range:

  1. Ratio error range:±0.001% ~ ±19.99%(two positions: 1.999%, 19.99%). Minimum resolution:0.001%.
  2. Phase error range:±0.01' ~ ±900'(two positions: 90.0',900'). Minimum resolution: 0.1'.
  3. Impedance range:0.001Ω~ 19.99Ω. Minimum resolution: 0.001Ω.
  4. Admittance:0.001 ms ~ 19.99 ms. Minimum resolution:0.001 ms.

c. Accuracy of Voltage and Current display: ±1%; Display range: 0-199,9%

d. The secondary impedance of standard current transformer connected with Tester ≤ 0.11Ω (cosφ = 1)

e. The secondary impedance of tested current transformer connected with Tester ≈ 0.003Ω (cosφ = 1)

f. Loading of standart volatge transformer connected to the tester ≈ 0

g. Polarity display current and voltage < 30% of nomal value

h. Power consumption: < 20VA

i. Rate Frequency:50Hz

j. Operation range: (1%-120%).In, (20%-120%).Un

k. Display model: LED

 

3)HLS-20G1 Standard Current Transformer (with the Current Source)

a. Rated primary current(A):5,7.5,10,15,20,25,30,40,50,60,75,80,100,120,150,160,200,250,300,315,400,500,600,630,750,800,1000,1200,1250,1500,1600,2000A

b. Rated secondary current:5A,1A

c. Accuracy calss: 0.01%

d. Rated secondary capacity:0.2 ohm (when I2=5A, P=5VA, when I2=1A, P=0.2VA)

e. Frequency:50Hz

f. Operating Range:(1%--120%).In

g. Connection model: Automatic connection by PC

h. Product structure: with the Current Source

i. Input voltage of the current source: AC 0-250V

j. Capacity of the current source: 10kVA

 

4)FY49 Current Transformer Burden

a. Rated Current: 5A

b. Operating Range: (1%--120%).In

c. Power Factor and Rated capacity (5A):

COSФ = 0.8: 1.25VA, 2.5VA ,5VA ,6.25VA ,7.5VA ,10VA ,12.5VA ,15VA ,20VA ,25VA,30VA

COSФ = 1.0: 1.25VA, 2.5VA ,5VA ,6.25VA ,7.5VA ,10VA

Power Factor and Rated capacity (1A):

COSФ = 0.8: 0.05VA, 0.1VA ,0.2VA ,0.25VA ,0.3VA ,0.4VA ,0.5VA ,0.6VA ,0.8VA ,1VA,1.2VA

COSФ = 1.0: 0.05VA, 0.1VA ,0.2VA ,0.25VA ,0.3VA ,0.4VA

d. Rate Frequency:50Hz

e. Accuracy Class: ±3%

g. Control model: Automatic control by PC & Manual control

 

5)FY47 Current Transformer Burden

a. Rated Current: 1A

b. Operating Range: (1%--120%).In

c. Power Factor and Rated capacity (VA):

COSФ = 0.8: 1.25VA, 2.5VA ,5VA ,6.25VA ,7.5VA ,10VA ,12.5VA ,15VA ,20VA ,25VA,30VA

COSФ = 1.0: 1.25VA, 2.5VA ,5VA ,6.25VA ,7.5VA ,10VA

d. Rate Frequency:50Hz

e. Accuracy Class: ±3%

g. Control model: Automatic control by PC & Manual control

 

6). CT Primary Testing Cables

3000Ax2.5mx1pc, 1000Ax2.5mx1pc, 500Ax2.5mx1pcs, 250Ax2.5mx1pc

 

7). CT Testing Software

  1. English Version
  2. The datas acquisition model: Automatic & Manual
  3. The format of the output reports according to the use`s require

 

 

 

 