Product Details:
Payment & Shipping Terms:
|
Keywords: | Digital Phase Angle Meter | Current Range: | 0-10A |
---|---|---|---|
Voltage Range: | 0-500V | Phase Angle: | 0-360 |
Frequency: | 45-65Hz | Class: | 1 |
Usage: | Instruments Measurement And Protection Relay Testing | Weight: | 0.5KG |
Application
Applicable to relay protection, electric power measure, electric power construction and conversion engineering and other professional, is the electric power department, factories and mines, the petroleum chemical industry, the metallurgy system for the secondary circuit check ideal electric meters.
Introduction
GF211 double clamp digital phase angle meter is a multi-functional portable instrument. It can measure not only alternating voltage, but also alternating current. Its important function is to measure phase angle between two voltages, between two current or between voltage and current. The current signal is obtained by the clamp current transformer without cutting off current wire. It can discern inductive circuit and capacitive circuit; can directly read differential protection phase among every unit of CT; can check connection of transformer; measure three way voltage phase sequence; can check whether the meter connection is right or not; can evaluate the running speed of electric kWh meter. It has high resolution of current, so can be used as a leakage current meter. It is an ideal choice for electric power bureau, factories, mine, petroleum -chemistry enterprises, metallurgy factories and so on.
GF211 with high precision small clamps head to improve current precision measuring clamp, facilitate field wiring a dense environment is used.
Electrical parameters | |
---|---|
Accuracy class | 1%, 2% |
Power supply | Two 9V batteries |
Scale | |
Phase | 0-360° |
AC Voltage | 500V |
AC Current | 200mA/2A/10A |
Fundamental error (under standard operating environment) | |
Temperature | 23°C±5°C |
Moisture | <65% |
Wave form | Sine wave Distortion ≤1% |
Frequency | 50± 2Hz, 60± 2Hz |
Wire position | Center of clamp |
Phase measurement | Voltage: 100V± 25V Current: 1A±0.2A |
Phase accuracy | 1.0% FS |
Electrical parameters - continued | |
Fundamental error (under standard operating environment) - contiued | |
Voltage accuracy | |
200V | 1.0FS, Resolution: 0.1V |
500V | 1.0FS, Resolution: 1V |
Voltage accuracy | |
10A | 2.0FS, Resolution: 10mA |
2A | 2.0FS, Resolution: 1mA |
200mA | 2.0FS, Resolution: 0.1mA |
Input impedance | |
When measure voltage | 1MΩ |
Input voltage impedance | >120KΩ when measure phase |
Phase measurement | |
Voltage accuracy | 3V-500V |
Current range | 0.01A-10A |
Additional error | |
Measure phase angle, the voltage and the current | Less than the fundamental error |
Measure current | The error led by wires away from center of clamps is less than the fundamental error |
Safety specification | |
Resistance to voltage | The meter can resist 1000V (AC sine wave, 50Hz or 60 Hz) for 1 minute between the meter circuit and the meter case; Between input joint U1 and U2 can resist 500V (AC sine wave, 50Hz or 60 Hz) for 1 minute. |
Insulation resistance | The resistance both between the meter circuit and the meter surface and between the terminals U1 and U2 is greater than 100MΩ. |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 185×167×35 |
Weight (kg) | 0.5 |
Environmental conditions | |
Working temperature | 0°C±40°C |
Humidity | ≤80% |
Accessory | |
Double clamp phase volt-ampere meter | 1 piece |
Clamps 10A | 2 pieces |
Clamp wire | 2 pieces |
Voltage wire | 2 pieces |
User's manual | 1 piece |
Accessory - continued | |
Certification of quality | 1 piece |
Box | 1 piece |
Well and High Quality Control ,
Prompt Delivery ,
New Product ,
Competitive Prices ,
Earth-friendly Products ,
Small Order Acceptable ,
OEM Accepted