Home ProductsPower Calibrator

GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER

Certification
Good quality Current Transformer for sales
I'm Online Chat Now

GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER

China GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER supplier
GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER supplier GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER supplier GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER supplier GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER supplier

Large Image :  GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER

Product Details:

Place of Origin: BEIJING CHINA
Brand Name: GFUVE
Certification: ISO9001, CE, UL, KEMA
Model Number: GF302D

Payment & Shipping Terms:

Minimum Order Quantity: 1sets
Price: 30000USD
Packaging Details: STANDARD EXPORT WOODEN BOX
Delivery Time: 2-3WEEKS
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 200SETS/MONTH
Contact Now
Detailed Product Description
ACCURACY: 0.02% U: 0-600V AC
I: 0-120A AC F: 40-70HZ
PHASE ANGLE: 0-360.000 PF: -0-0-1
WEIGHT: 28KG LCD: 7' TOUCH COLOR TFT LCD
TYPE: POWER CALIBRATOR AND TESTER HARMONICS: 2-51th

GF303D GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER

GFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTERGFUVE 120A 600V High Precision Portable THREE-PHASE POWER CALIBRATOR AND TESTER

The GF302D three-phase power calibrator and tester is used for the adjusting, checking and verification of measuring instruments such as; electricity meters, frequency, voltage and current protective relays, current transformers and clamps, active and reactive power meters, phase meters, frequency meters, ammeters, voltmeters, transducers, monitoring systems and power quality analyzers.
The GF302D is a single/three phase source of AC current and voltage with an accuracy class of 0.02 or 0.05, and programmable values for harmonics. It generates voltages up to 560V in sub-ranges 70V, 140V, 280V, and 560V. Current is available up to 120A in sub-ranges 0.5A, 6A, 20A, and 120A. Frequency ranges from 40Hz to 500Hz, and phase angle from 0 to 360°. In a single phase connection it can generate current up to 360A.

The GF302D can automatically obtain the error characteristics for measurement values and time characteristics of protection relays electricity meters, standard S0 impulse input is used with the possibility of a photo scanning head connection. When testing transducers, current transformers and clamps, a DC input with ranges 10V/20mA and an AC input with ranges 10V/100mA/5A is used. For protective relay testing, three timers with start/stop inputs and resolution 1ms are utilized. Two additional binary outputs are used for operate/standby calibrator state signaling.

The calibrator is controlled by means of a personal computer running a Windows operating system with meter test system software installed.

The Model GF302D provides the functions required to fully test power quality meters. Harmonics and interharmonics may be added to both the voltage and the current outputs. In addition, all outputs may be configured to reproduce sags, swells and interruptions. Other power quality related phenomena such as flicker and notching may also be simulated.

The Model GF302D facilitates the testing of all types of energy meters by delivering precise, user defined quantities of energy to the meter under test. The Model GF302D is also able to accept a pulse input for testing meters equipped with this type of output. The Option GF302D Optical Rotation Detector may be used to measure the rotation of an electro-mechanical energy standard. Alternatively, the Option GF302D, Optical Port Adapter, may be used to access an energy meter's optical communications port. The Model 8100 may be used with the Model GF302D2 six channel counter/comparator to test up to six energy meters simultaneously. When used in the external energy reference mode, all UUT's may be simultaneously calibrated against a single external energy standard.

A menu-driven front panel and simple intuitive controls make the Model GF302D extremely easy to use. Output settings and menus are displayed on a large color LCD display. Power settings may be expressed in units of Volt-Amperes, Watts or VARs. Similarly the phase angle may be expressed as either degrees or power factor. Such flexibility allows the Model GF302D to be configured to meet the specific requirements of any user. A compact rugged design makes the Model GF302D ideally suited to a wide range of operating environments from the laboratory to the factory floor.

Unequaled performance, simplicity of operation, and flexible system configuration make the Model GF303D today's standard for power and energy calibration.

FEATURES

  • Min current output 1mA
  • Predefined multiple load points
  • Reference meter and power source integration
  • User friendly menu guided operation
  • Easy verification and analysis of meter installations
  • Automatic operation without need of an external PC
  • Generation of harmonics in current and voltage up to the 51th
  • Verification of the load conditions on metering installation
  • Verification of the energy registration
  • Automatic testing mechanical meter and electronic meter error
  • Voltage, current, frequency, phase angle, power factor, harmonics can be regulated
  • 1P2W, 1P3W, 3P3W, 3P4W can be set
  • 4 quadrant measurement
  • Three phase voltage source up to 560V
    Three phase current source up to 120A and single phase up to 360A
    Voltage and current harmonics programming up to the 64th
    Power quality parameters simulation
    Impulse input for electricity meters testing
    Start / stop inputs for protective relay testing
    AC measurement input for transformers an clamps testing
    DC measurement input for transducer testing
    RS232C interface and personal computer software GF302D
 

PARAMETERS

Electrical parameters 
Accuracy 0.02%, 0.05%, 0.1%
Power Supply Single phase AC 85-265V, frequency 50/60Hz.
AC Voltage Output 
Range(U1,U2,U3) 57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional); max 600V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.2% (Non-capacitive load)
Output load each phase 50VA
Accuracy 0.05%RG or 0.02%RG
AC Current Output 
Range(I1,I2,I3) 200mA, 1A, 5A, 20, 100A; max 130A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.2% (Non-capacitive load)
Output load 100VA
Accuracy 0.05%RG or 0.02%RG
Power Output  
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG or 0.02%RG
Reactive power measuring accuracy 0.1%RG
Phase Output  
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.02°
Power Factor 
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0. 0005
Frequency Output  
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.002Hz
Voltage /Current/Harmonic Setting Output
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error 
Active power energy 0.05%RG or 0.02%RG
Reactive power energy 0.1%RG
Power Pulse Output  
Power pulse type active pulse, reactive pulse
Active power pulse output 5V, 10mA
Power Pulse Input 
Energy pulse type support active and reactive pulse, the highest frequency power pulse input is 180K.
Communication Port
Communication Port RS232, USB2.0
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP20
Declaration of conformity CE certified
Mechanical parameters 
Dimensions (W×D×H) (mm) 445x460x158
Weight (kg) 28
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

http://www.gfuve.com/energy-meter-calibration/portable-three-phase-electric-meter-test-bench.html

Contact Details
Beijing GFUVE Electronics Co.,Ltd.

Contact Person: Mr. Andy

Tel: 86-10-85782698

Fax: 86-010-85781298

Send your inquiry directly to us (0 / 3000)