Product Details:
Payment & Shipping Terms:
|
| Measuring Current Range: | 0-120A | Measuring Voltage Range: | 0-500V |
|---|---|---|---|
| Accuracy Class: | 0.05% | Operating Temperature: | -20~+70°C |
| Dimensions: | 450×320×185 | Sample Price: | Depending On Exchange Rate Fluctuations |
| Category: | Power Meters |
| Electrical parameters | |
|---|---|
| Accuracy | 0.02%, 0.05%, 0.1% |
| Power Supply | Single phase AC 85-265V, frequency 50/60Hz. |
| AC Voltage Output | |
| Range(U1,U2,U3) |
57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional); max 500V |
| Adjustment range | (0-120)%RG(1) |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | 0.01%/120s |
| Distortion | 0.2% (Non-capacitive load) |
| Output load | each phase 25VA |
| Accuracy | 0.05%RG or 0.02%RG |
| AC Current Output | |
| Range(I1,I2,I3) | 200mA, 1A, 5A, 20A, 100A; max 120A |
| Adjustment range | (0-120)%RG |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | <0.01%/120s |
| Distortion | ≤0.2% (Non-capacitive load) |
| Output load | 50VA |
| Accuracy | 0.05%RG or 0.02%RG |
| Power Output | |
| Active power output stability | <0.01%RG/120s |
| Reactive power output stability | <0.02%RG/120s |
| Active power measuring accuracy | 0.05%RG or 0.02%RG |
| Reactive power measuring accuracy | 0.1%RG |
| Phase Output | |
| Output adjustment range | 0°-359.999° |
| Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
| Resolution | 0.01° |
| Accuracy | 0.02° |
| Power Factor | |
| Adjustment range | -1 ~ 0 ~ 1 |
| Resolution | 0.0001 |
| Measurement accuracy | 0. 0005 |
| Frequency Output | |
| Adjustment range | 40Hz-70Hz |
| Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
| Resolution | 0.001Hz |
| Accuracy | 0.002Hz |
| Voltage /Current/Harmonic Setting Output | |
| Harmonic number | 2-51times |
| Harmonic content | 0-40% |
| Harmonic phase | 0-359.99 |
| Harmonic setting accuracy | (10%±0.1%)RD(2) |
| Power Energy Measurement Error | |
| Active power energy | 0.05%RG or 0.02%RG |
| Reactive power energy | 0.1%RG |
| Power Pulse Output | |
| Power pulse type | active pulse, reactive pulse |
| Active power pulse output | 5V, 10mA |
| Power Pulse Input | |
| Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
| Communication Port | |
| Communication Port | RS232, USB2.0 |
| Safety | |
| Isolation protection | IEC 61010-1:2001 |
| Measurement Category | 300 V CAT III, 600 V CAT II |
| Degree of protection | IP20 |
| Declaration of conformity | CE certified |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 480x500x185 |
| Weight (kg) | 27 |
|
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
|