Electrical parameters |
|
Accuracy class |
0.05%, 0.1% |
|
Power supply |
Single phase AC 220V±10% or 110V±10%, 50/60Hz |
|
Communication port |
USB, RS232, RS485, LAN |
|
AC Voltage output |
|
Range(U1,U2,U3) |
50V, 100V, 200V, 400V, 600V |
|
Adjustment range |
(0 - 120)% RG |
|
Adjustment resolution |
0.01% RG, 0.1% RG, 1% RG, 10% RG |
|
Stability |
0.01% /1min |
|
Distortion |
≤0.2% (non-capacitive load) |
|
Max. output load |
25VA for each phase |
|
Accuracy |
0.05% RG |
|
AC Current output |
|
Range(I1,I2,I3) |
0.5A, 1A, 2.5A, 5A, 10A, 20A |
|
Adjustment range |
(0 - 120)% RG |
|
Adjustment resolution |
0.01% RG, 0.1% RG, 1% RG, 10% RG |
|
Stability |
0.01% /1min |
|
Distortion |
≤0.2% (non-capacitive load) |
|
Max. output load |
25VA for each phase |
|
Accuracy |
0.05% RG |
|
AC Power output |
|
Active output stability |
0.01%RG/1min |
|
Reactive output stability |
0.02%RG/1min |
|
Active accuracy |
0.05% RG |
|
Reactive accuracy |
0.1% RG |
|
Frequency output |
|
Adjustment range |
45-65Hz |
|
Adjustment resolution |
1Hz, 0.1Hz, 0.01Hz and 0.001Hz |
|
Resolution |
0.001Hz |
|
Accuracy |
0.002Hz |
|
Power factor output |
|
Adjustment range |
-1 to 0 to +1 |
|
Adjustment resolution |
0.0001 |
|
Resolution |
0.0005 |
|
Phase output |
|
Adjustment range |
0°-359.999° |
|
Adjustment resolution |
10°, 1°, 0.1°, 0.01° |
|
Resolution |
0.001° |
|
Accuracy |
0.05° |
|
Harmonic configuration |
|
Times |
2 to 31 |
|
Content |
0-40% |
|
Phase |
0°-359.999° |
|
Configuration error |
(10% RD + 0.1%), RD refers to the configuration value of harmonic contents |
|
DC Voltage output |
|
Range |
75mV, 75 V, 150 V, 300 V, 500V, 1000 V |
|
Adjustment range |
(0-120)% RG |
|
Adjustment resolution |
0.01% RG, 0.1% RG, 1% RG, 10% RG |
|
Stability |
0.01% RG / 1 min |
|
Distorting |
≤0.2% (non-capacitive load) |
|
Output load |
25VA |
|
Accuracy |
0.05% RG |
|
Ripple contents |
≤1% |
|
DC Current output |
|
Range |
0.5 A,1A, 2.5 A, 5 A, 10A, 20 A |
|
Adjustment range |
(0-120)% RG |
|
Adjustment resolution |
0.01% RG, 0.1% RG, 1% RG, 10% RG |
|
Stability |
0.01% RG / 1min |
|
Distortion |
≤ 0.2% (non-capacitive load) |
|
Output load |
25VA |
|
Accuracy |
0.05% RG |
|
Ripple contents |
≤1% |
|
Energy Error |
|
Active error |
0.05% RG |
|
Reactive error |
0.1% RG |
|
DC Input Voltage Measurement |
|
Range |
0 to ±20V |
|
Measurement range |
(0-120)% RG |
|
Accuracy |
0.01% RG |
|
Resolution |
0.001% RG |
|
DC Input Current Measurement |
|
Range |
0-20mA |
|
Measurement range |
(0-120)% RG |
|
Accuracy |
0.01% RG |
|
Resolution |
0.001% RG |
|
Mechanical parameters |
|
Dimensions (W×H×D) (mm) |
460x430x185 |
|
Weight (kg) |
20 |
|
Environmental conditions |
|
Working temperature |
0°C to 40°C |
|
Relative humidity |
≤85% |