The FU2200A digital power meter is a range of economical yet highly functional three-phase multifunction power and energy meters manufactured by GFUVE. These meters provide excellent value for monitoring power and energy management systems. The 2200A digital power meter may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port running the Modbus RTU protocol. With a wide range of models to choose from, the 2200A digital power meter offers unparalleled value and functionality.
Features
Applications
Parameter | Accuracy | Resolution | Range | |
Voltage | 0.2% | 0.01V | 0.5~500kV | |
Current | 0.2% | 0.01mA | 5mA~50000A | |
Active Power | 0.5% | 0.2W | -9999MW~+9999MW | |
Reactive Power | 2% | 0.2var | -9999Mvar~+9999Mvar | |
ApparentPower | 0.5% | 0.2VA | 0~9999MVA | |
Active Power Demand | 0.5% | 0.2W | -9999MW~+9999MW | |
Reactive Power Demand | 2% | 0.2var | -9999Mvar~+9999Mvar | |
Apparent Power Demand | 0.5% | 0.2VA | 0~9999MVA | |
Power Factor | 0.005 | 0.0001 | -1.0000~0~1.0000 | |
Frequency | 0.01Hz | 0.01Hz | 45.000~65.000Hz | |
Energy | Primary | 0.5% | 0.1kWh | 0~99999999.9kWh |
Secondary | 0.001kWh | 0~999999.999kWh | ||
Reactive Energy | Primary | 2% | 0.1kvarh | 0~99999999.9kvarh |
Secondary | 0.001kvarh | 0~999999.999kvarh | ||
Apparent Energy | Primary | 0.5% | 0.1VAh | 0~99999999.9kVAh |
Secondary | 0.001VAh | 0~999999.999kVAh | ||
Phase Angle | 0.1° | 0.01° | 0~359.99° | |
Unbalance Factor | 2% | 0.01% | 0~300.00% | |
PT | 1 | 1~10000 | ||
CT | 1 | 1~10000 | ||
Addr | 1 | 1~254 |
Current Input
Rated Current 5A/1A ac Measurement Range 0~6A ac
Overload capacity 20Acontinuous, 50A 10Sec, 100A 1Sec Burden 0.5VA @5A RMS
Current start 0.1%Rated valueAccuracy0.2%
Voltage Input
Rated voltage 400Vac L-N, 690Vac L-L Input Impedance 1MΩper phase
Overload capacity 1500Vac continuous,2500Vac 50/60Hz 1min Frequency 45Hz~65HzAccuracy 0.2%
Energy Accuracy
Active class 0.5S (IEC62053-22,GB/T17215.322-2008)
Reactive class 2 (IEC62053-23)
Power Supply (AC/DC)
Range 85~265Vac,50/60Hz;100~300VdcPower Consumption:5W
Insulation voltage capacity2000Vac,50/60Hz,1min
Working condition
Operation Temperature -25°C~+70°CStorage Temperature -40°C~+85°C
Relative Humidity 5% ~ 95%( non-condensing)