Home ProductsPhase Angle Meter

10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter

Certification
Good quality Current Transformer for sales
I'm Online Chat Now

10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter

China 10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter supplier
10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter supplier 10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter supplier 10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter supplier 10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter supplier 10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter supplier

Large Image :  10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter

Product Details:

Place of Origin: Beijing, China (Mainland)
Brand Name: GFUVE
Certification: CE/ISO9001
Model Number: GF211B

Payment & Shipping Terms:

Minimum Order Quantity: 1SET
Price: FCA USD 500-1000/ set
Packaging Details: Standard Export Box
Delivery Time: 3days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 10000units/Months
Contact Now
Detailed Product Description
Class: 0.5 Phase Angle: 0-360.0
Current Range: 0-10A Voltage Range: 0-500V
Frequency: 45-65Hz Types: Digital Phase Angle Meter
Weight: 0.26kg Clamp: Two, 8mm Diameter
Active Power: 0.5%
High Light:

digital meter

,

phase meter

,

phase angle meter

GF211B 10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter

(Accuracy 0.5%)

10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter10A 500V class 0.5 Multi-function Double Clamp Digital Phase Angle Meter

Application

GF211B multi-function double clamp digital phase angle meter is a multi-functional portable instrument. It can measure not only alternating voltage (U), but also alternating current (I), frequency (F), active power (P), reactive power (Q), power factor (PF) and so on. Its important function is to measure phase angle between two voltages, between two current or between voltage and current. The current signal is obtained by the clamp current transformer without cutting off current wire. It can discern inductive circuit and capacitive circuit; can directly read differential protection phase among every unit of CT; can check connection of transformer; measure two way voltage phase sequence; can check whether the meter connection is right or not; can evaluate the running speed of electric kWh meter. It has high resolution of current, so can be used as a leakage current meter. It is an ideal choice for electric power bureau, factories, mine, petroleum -chemistry enterprises, metallurgy factories and so on.

Specifications

2.1 Scale

2.1.1 Phase: 0~360°

2.1.2 AC Voltage: 0~500V

2.1.3 AC Current: 200mA / 2A / 10A

2.1.4 Frequency: 45~65Hz

2.1.5 Active power accuracy: 0.5%, resolution 0.01W

2.1.6 Power factor: -1~0~1, resolution 0.001

2.2 Fundamental error (under standard operating environment)

2.2.1 Standard Condition

Temperature

Moisture

Wave Form

Frequency

Wire Position

Phase measurement

voltage

current

23℃±5℃

<65%

Sine wave Distortion ≤1%

50± 2Hz, 60± 2Hz

center of clamp

100V± 25V

1A±0.2A

2.2.2 Phase accuracy 1.0% FS

2.2.3 Voltage accuracy

Scale

Accuracy

Resolution

200V

1.0FS

0.1V

500V

1.0FS

1V

2.2.4 Current accuracy

Scale

Accuracy

Resolution

10A

1.0FS

10mA

2A

1.0FS

1mA

200mA

1.0FS

0.1mA

2.3 Input impedance:

2.3.1 1MΩ when measure voltage

2.3.2 input voltage impedance>120KΩ when measure phase

2.4 operation condition

Temperature

Moisture

Phase measurement

voltage range

Current range

0℃±40℃

≤80%

2V-500V

0.005A-10A

2.5 additional error

2.5.1 When measure phase angle, the voltage and the current are in the range of the operating conditions, the additional error is less than the fundamental error.

2.5.2 When measure current, the error led by wires away from center of clamps is less than the fundamental error.

2.6 Safety specification

2.6.1 Resistance to voltage

The meter can resist 1000V (AC sine wave, 50Hz or 60 Hz) for 1 minute both between the meter circuit and the meter case; Between input joint U1 and U2 can resist 500V (AC sine wave, 50Hz or 60 Hz) for 1 minute .

2.6.2 Insulation resistance

The resistance both between the meter circuit and the meter surface and between the terminals U1 and U2 is greater than 100MΩ.

2.7 Power supply 3.7V batteries.

2.8 Size and Weight: 185 mm×85mm×41mm 0.26Kg

Accessories

  

No

Name

Number

1

multi-function double clamp digital phase angle meter

1

2

Clamps 10A

2

3

Clamp wire

2

4

Voltage wire

2

5

User's manual

1

6

Certification of quality

1

7

Box

1

Contact Details