Product Details:
Payment & Shipping Terms:
|
P18: | Current Probes For Oscilloscope | Ratio: | 1000: 1 Or 2000:1 (customized) |
---|---|---|---|
Accuracy Class: | 0.1%, 0.2% | Primary Current: | 0 - 100A AC |
Secondary Current: | 0 - 100mA AC (customized) | Max. Cont. Input: | 120A |
Load Capacity: | ≤4Ω | Frequency Range: | 0Hz-2MHz |
Max. Voltage Not: | 600 V |
COMPANY PROFILE
Beijing GFUVE Electronics Co., Ltd. was established in 2005. It combined science, industry and trade together as one high-tech enterprise. GFUVE mainly produces high voltage ammeter recorder, IEC61850 test suite software, meter test equipment, reference standard meter, phantom load power source, electrical measurement instrument, relay test set, transformer test, and power analyzer, intelligent digital meter, transducer and current transformer models etc.
GFUVE is a leader manufacturer of energy meter test products and high voltage ammeter recorder in China. It is professional in energy meter test system, energy meter portable tester and related accessory. The product of high voltage ammeter recorder develops very quickly in the market. Our company has achieved certification to ISO9001. The products are sold to over 30 provinces in China and exported to overseas including South America, Middle East, Southeast Asia and Africa.
We have been contributing ourselves to developing the durable and stable products for the usage of the power system. Contact us now for further business relationship. We are here to provide you the best service.
P18 high precision 2M bandwidth 100A current probes for oscilloscope
Product introduction
The round jaw design on the P18 Series AC current clamp along with the high content nickel metal core makes them well suited for power quality applications where high accuracy and low phase shift along with wide frequency are important. Measurement range is 1mA to 120A. The P18 is a general purpose 100A AC current clamp designed for use with DMMs, power loggers and energy meter calibration instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The P18 has an integral 2.5m lead terminated. The rounded jaw design on this current clamp makes it well-suited for power applications where high accuracy 0.1% and low phase shift and wide frequency response are important..
APPLICATIONS
PARAMETERS
Parameters
Electrical parameters | |
---|---|
Ratio | 1000: 1 or 2000:1 (customized) |
Accuracy class | 0.1%, 0.2% |
Primary current | 0 - 200A AC |
Secondary current | 0 - 200mA AC (customized) |
Max. Cont. Input current | 240A |
Load capacity | ≤4Ω |
Over voltage category | CAT III 600V |
Output signal (AC current) | From 0 to 200mA AC at nominal input current |
Output signal (AC voltage) | From 0 to 2V AC at nominal input current |
Frequency range | 40Hz-2000Hz |
Dielectric strength | 3KV 50Hz/60Hz at 1minute |
Temperature range | -20°C to +55°C |
Output | 2.5 meter cable with D01 connector |
Max. voltage not insulated conductors | 600 V |
Standard | EN 61010-1, EN 61010-2-032, IEC60044-1 |
Installation | Clamp type |
Output mode | Lead output(2.5m) |
Mechanical parameters | |
Dimensions (L x W x H) (mm) | 52.5 x 137.5 x 28 |
Weight (g) | 400 |
Holding wire diameter (mm) | φ20 |
Max. jaw opening (mm) | 20 |
Jaw color | Red, yellow, blue, green, black |