Home ProductsRelay Test Set

PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test

Certification
Good quality Current Transformer for sales
I'm Online Chat Now

PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test

China PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test supplier
PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test supplier PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test supplier PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test supplier PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test supplier

Large Image :  PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test

Product Details:

Place of Origin: Beijing, China
Brand Name: GFUVE
Certification: ISO 9001 : 2008; CE; UL
Model Number: TEST-330T

Payment & Shipping Terms:

Minimum Order Quantity: 1SET
Price: USD20000-35000
Packaging Details: Standard export wooden box
Delivery Time: whitin 20 days
Payment Terms: T/T, Western Union, Paypal, L/C, D/A, D/P
Supply Ability: 200pcs/month
Contact Now
Detailed Product Description
TYPES: THREE PHASE PROTECTION RELAY TESTER ACCURACY: 0.1%
U: 0-300v DC, 0-260v AC I: 0-90A Max AC , 0-20A Max DC
Output: Ua Ub Uc Ux Uy, Ia Ib Ic Frequency: 0-1050Hz
Phase Angle: 0-360.00 LCD: 8.4' TFT Color LCD
Warranty: 3years Weight: 16..6KG

TEST-330T PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test

The Test-330T three phase secondary current injection tester is the first choice for applications requiring very high accuracy more than 0.1%. This unit is not only an excellent test set for protection devices of all kinds but also a universal calibrator. It can as a ac or dc current source and voltage.
Its unique accuracy and reliability make the Test-330B ideal for protection and measurement equipment manufacturers for research and development, production and electric power company type testing.
 
The Test-330T is a multipurpose, light-weight, field portable test set capable of testing a wide variety of electro-mechanical, solid-state and microprocessor-based protective relays, motor overload relays and similar protective devices.
The unit can be operated either manually via the built-in touch-screen user interface, or placed under full computer control via the AVTS, Advanced Visual Testing Software, or the RTMS, Relay Test Management Software, running on a PC.
The built-in user interface, called the Smart Touch-View Interface™, is Megger’s second generation of automatic / semi-automatic manual user interface running the new RTMS software. It incorporates a large, easy to read Full Color high resolution, high definition, TFT LCD touch-screen display, which displays metered values such as AC and DC Amperes, AC and DC Volts, and Time in both seconds and cycles. Depending on the type of test selected, other values may be displayed, such as Phase Angle, Frequency, Ohms, Watts, VA, or Power Factor.
 

FEATURES

  • Embedded host machine equipped with Complex Programmable Logic Device (CPLD)
  • Eight-path synchronous D/A output in a single machine
  • High-accuracy linear power amplifier
  • Host machine integrated single cabinet structure with big LCD screen and complete interface has obtained appearance patent
  • Intelligent self-protection function
  • Plentiful Binary and powerful software function
  • Easily complete the ABB, Siemens, AREVA, Schneider, GE, SEL, VAMP, Toshiba, NR, Sifang and other foreign manufacturers of protective device test
  • Synchronous output of five-phase voltage and three-phase current, Max AC current output is 90A, Max AC voltage output is 260V
 
 

OVERVIEW

  • 3 phase current output
  • 5 phase voltage output
  • 8 binary input, 4 binary output
  • Accuracy more than 0.1%
 

TEST ITEM

  • U/I test
  • DC test
  • Impedance characteristics
  • Power direction test
  • I-T test
  • Differential relay
  • Harmonic test
  • Differential protection
  • Distance protection
  • Zero sequence protection
  • Setting group test
  • State sequence
  • Synchronization test
  • Special test
  • Oscillation test
  • Metering instrument
  • Hardware checkout
  • Low Voltage protection
  • Fault Waveform Reproduction
 

PARAMETERS

Electrical parameters
Power voltageAC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement0.1ms-999999.999s
AC current output 
Phase current output (effective value)3 x 0-30A
Maximum power output260VA/phase
Maximum parallel current output (effective value)0-90A
Long-term allowable working value of phase current
(effective value)
>10A
Allowable working time of maximum current>11s
Accuracy class<±0.1%
AC voltage output 
Phase voltage output (effective value)5 x 0-130V
Line voltage output (effective value)0-260V
Maximum power output70VA/phase
Accuracy class<±0.1%
DC current output 
Output range-10 to 10A or 3 x 0 to ±10A
Maximum power output200VA
Accuracy class<±0.1%
DC voltage output 
Output range0-300V or 5 x 0 to ±130V
Maximum output power130VA
Accuracy class<±0.1%
Binary input 
Idle contact1-20mA, 24V (DC)
Electric potential contact250V/0.5A (DC)
Binary output 
Idle contact250V/0.5A (DC)
Rated output 
Frequency error<±0.01Hz
Phase error<±0.1%
Waveform distortion<±0.3% (fundamental wave)
Time error<40µs
Output frequency0-1050Hz
Superposed harmonic wave0-21times
Mechanical parameters 
Dimensions (L×W×H) (mm)360x195x375
Weight (kg)16.6
Environmental conditions
Use range0°C to 45°C
Storage range-25°C to 70°C

http://gfuve.com/relay-tester/three-phase-secondary-current-injection-test-set.html 

Company introduction

Global wholesales LZCK322-10 200/5a high voltage Split Core ct Current Transformers 5a

Flow chart

Global wholesales LZCK322-10 200/5a high voltage Split Core ct Current Transformers 5a

Certifications

Global wholesales LZCK322-10 200/5a high voltage Split Core ct Current Transformers 5a

Packaging & Shipping

Global wholesales LZCK322-10 200/5a high voltage Split Core ct Current Transformers 5a

Our services

Global wholesales LZCK322-10 200/5a high voltage Split Core ct Current Transformers 5a

PORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic testPORTABLE THREE PHASE SECONDARY CURRENT INJECTION PROTECTION RELAY TESTER WITH Harmonic test 

Contact Details
Beijing GFUVE Electronics Co.,Ltd.

Contact Person: Mr. Andy

Tel: 86-10-85782698

Fax: 86-010-85781298

Send your inquiry directly to us (0 / 3000)