Home ProductsCT Analyzer

China wholesales high precision portable instrument transformer turn ratio test set

Certification
Good quality Current Transformer for sales
I'm Online Chat Now

China wholesales high precision portable instrument transformer turn ratio test set

China China wholesales high precision portable instrument transformer turn ratio test set supplier
China wholesales high precision portable instrument transformer turn ratio test set supplier China wholesales high precision portable instrument transformer turn ratio test set supplier China wholesales high precision portable instrument transformer turn ratio test set supplier

Large Image :  China wholesales high precision portable instrument transformer turn ratio test set

Product Details:

Place of Origin: BEIJING
Brand Name: GFUVE
Certification: ISO9001
Model Number: GF061R

Payment & Shipping Terms:

Minimum Order Quantity: 1set
Price: 8000USD/set
Packaging Details: standard export box
Delivery Time: 1-2weeks
Payment Terms: D/A, D/P, L/C, T/T, Western Union, MoneyGram
Supply Ability: 200sets/month
Contact Now
Detailed Product Description
CLASS: 0.05 CT Ratio: 0-50000
PT Ratio: 0-10000 Phase Angle: 0-90
Weight: <5KG Color: Yellow
Reference Standards: IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13 Dimension: 280mm X 246mm X 158mm
LCD: 6.4inch Power Supply: AC 220V±10% Or AC 120V±10%, 50/60Hz

GF1061R INSTRUMENT TRANSFORMER TURNS RATIO TEST SET

GF1061R portable instrument transformer turns ratio test set is mainly used for field or lab testing of current transformers and voltage transformers, it can fully automatic test CT and PT turns ratio. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. Test quickly, operation simply.

China wholesales high precision portable instrument transformer turn ratio test setChina wholesales high precision portable instrument transformer turn ratio test set

PARAMETERS

Environmental conditions
Accuracy 0.2%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz
Voltage Range 0-100Vrms
Resolution 0.1V
Current Range 0-500mA
Current accuracy ±1mA, ±1% of reading ±1 digit
CT PT Turns ratio 0.8-10000
CT PT turns ratio Accuracy ±0.2%
Phase angle measurement 0-90°
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2/3/4/6
Reference standards
Overall dimension (L x W x H) (mm) 280 x 246 x 158
Weight (kg) ≤5
Environmental conditions
Relative humidity Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤2000m

 

http://gfuve.com/transformer-test/portable-ct-1061R.html

China wholesales high precision portable instrument transformer turn ratio test set

Contact Details
Beijing GFUVE Electronics Co.,Ltd.

Contact Person: Mr. Andy

Tel: 86-10-85782698

Fax: 86-010-85781298

Send your inquiry directly to us (0 / 3000)